Re: HVAC dead - 1986 L7 (archive)
[ Follow Ups ] [ 7-series (E23) Message Board ] [ Msg. Board FAQ ]
Posted by Tom M. on April 08, 2001 at 00:07:48:
In Reply to: HVAC dead - 1986 L7 posted by Randy on April 07, 2001 at 14:17:46:
(posted from: dap-208-166-66-182.erie-tnt-1.pa.erie.net (208.166.66.182))
Last night the HVAC died. No LEDs, no relay clicking, no blower activity. Not even on defrost mode. One moment it was on, next moment off. Almost as if the fuse blew. The #16 & #17 fuse is good along with the mini 5 amp one near the glovebox. I have 12 volts at the gr/br wire at the blower. Microswitch tested ok via an ohm meter. I'm at a loss. Any suggestions?Randy
1986 L7 239,000miles
Pull off the front cowl cover to get at the blower and check the high speed AC relay mounted to the right side of the right cover. You can swap this with another relay in fuse box to check. Default defrost mode is routed through this relay and if its gone you will have the problem you describe.
Check it out and let us know.
Good Luck,
Tom in PA
Follow Ups:
[ Follow Ups ] [ 7-series (E23) Message Board ] [ Msg. Board FAQ ]