Have you tried tightening the nuts? (m) (archive)
[ Follow Ups ] [ E30 M3 Message Board ] [ Msg. Board FAQ ]
Posted by John A on June 29, 2002 at 23:24:53:
In Reply to: Help! Temp. gauge twitching................. posted by Mark B. on June 29, 2002 at 12:12:22:
(posted from: knoxmax4-d-177.planetc.com (207.65.110.177))
There are two nuts that hold the gauge to the circuit board. Once contact is lost, the needle will read higher than it should. An intermittent contact will cause the needle to twitch. The same applies to the fuel gauge. Remove the cluster and tighten those suckers.
John
88 ///M3 CinnabarI think it might be a bad SI board, but is that the only solution to change it out or could it be something else. Thanks for your advice.
Mark B.
'89 M3
Follow Ups:
[ Follow Ups ] [ E30 M3 Message Board ] [ Msg. Board FAQ ]